Number of air exchanges per hour |
Table 1. Number of air exchanges per hr (Ec), determined with CO2, (100%) as tracer gas and the time (in hours and days) required for one exchange of the headspace volume (Ec-1) for different container types. All values are the mean of 4 replicates (STD: standard deviation).
|
Container type (description) |
Ec(h-1) (STD) |
Ec -1 in h |
Ec -1 in days |
|
1. body: Meli-jar with a nick in the glass rim closure: PP screw on lid with sampling device (rubber septum) |
1.20 (0,32) |
0.1832 |
0.035 |
|
2. body: Meli-jar without nick closure: idem 1 + rubber ring between body and closure |
5.83. 10-3 (6.05. 10-3) |
171.6 |
7.150 |
|
3. body: idem 2 + sampling device (rubber stopper) closure: idem 2 + clamp system |
5.53.10-4 (3,32.10-4) |
1806 |
75.26 |
|
4. body: idem 3 closure: PP membrane (15µm) + rubber ring between body and closure + clamp system |
2.4. 10-3 (2.2. 10-3) |
423.6 |
17.15 |

Fig.1. equipment for the experiment